Problem or Symptom

Possible Cause

Probable Correction

Low capacity

Dirty condenser

Clean condenser

Air temperature intake to condenser
very high

Re-orient condenser to avoid hot air
intake

Water temperature intake to ice making
section very high

Check for hot water supply to ice
machine due to mal-functioning or
non-existent hot water check valve at
dishwashing sink

Ice broken up and stuck between
reservoir and curtain, happens almost
every cycle

Ice thickness set too thin

Ice very uneven, check superheat

Slow harvest, check headmaster

Storage bin or dispenser not holding ice
properly

Check drains for water flow from ice
machine (separate to correct) or
restriction

High volume of drinks dispensed, cold
plate melting ice

Suggest pre-cooler for water supply to
cold plate

Vapor inlet valve leaks through slightly
during the freeze cycle

Check valve body for similar
temperatures on inlet and outlet, the
outlet should be colder and frost
develops on the tubes to the
evaporators

Exceeding maximum freeze time,
compressor unit trips on high discharge
temp

Check condenser bypass valve

Poor ice formation - very cloudy
and misshapen

Dirty water system

Clean the water distributor to remove
built up mineral scale

Low refrigerant charge.

Add several pounds of refrigerant to
check. If low on charge, locate leak.
Recover refrigerant, repair leak, replace
drier, evacuate to 300 microns and
weigh in the nameplate charge.

Whistling noise at CP unit during
harvest

By pass and liquid inlet valve coils not
getting power

Check harness