Service diagnosis – Scotsman 600 Prodigy Eclipse User Manual
Page 46

Service Diagnosis
Prodigy Eclipse
ä 600, 800, 1000
February 2008
Page 46
Problem or Symptom
Possible Cause
Probable Correction
Low capacity
Dirty condenser
Clean condenser
Air temperature intake to condenser
very high
Re-orient condenser to avoid hot air
intake
Water temperature intake to ice making
section very high
Check for hot water supply to ice
machine due to mal-functioning or
non-existent hot water check valve at
dishwashing sink
Ice broken up and stuck between
reservoir and curtain, happens almost
every cycle
Ice thickness set too thin
Ice very uneven, check superheat
Slow harvest, check headmaster
Storage bin or dispenser not holding ice
properly
Check drains for water flow from ice
machine (separate to correct) or
restriction
High volume of drinks dispensed, cold
plate melting ice
Suggest pre-cooler for water supply to
cold plate
Vapor inlet valve leaks through slightly
during the freeze cycle
Check valve body for similar
temperatures on inlet and outlet, the
outlet should be colder and frost
develops on the tubes to the
evaporators
Exceeding maximum freeze time,
compressor unit trips on high discharge
temp
Check condenser bypass valve
Poor ice formation - very cloudy
and misshapen
Dirty water system
Clean the water distributor to remove
built up mineral scale
Low refrigerant charge.
Add several pounds of refrigerant to
check. If low on charge, locate leak.
Recover refrigerant, repair leak, replace
drier, evacuate to 300 microns and
weigh in the nameplate charge.
Whistling noise at CP unit during
harvest
By pass and liquid inlet valve coils not
getting power
Check harness