beautypg.com

Owner’s manual, Venting installation, Continued – Desa CDVBN(A) User Manual

Page 13

background image

13

105501

OWNER’S MANUAL

VENTING
INSTALLATION

Continued

Figure 26 - Horizontal Termination
Configuration for Rigid Venting

Figure 27 - Horizontal Termination Configuration for Rigid Venting Using One
90

°

Elbow

Horizontal Venting

Vertical (V)

Horizontal (H)

37" min.

29" max.

(30

°

and 90

°

only, no vertical pipe)

48" min.

41" max.

(30

°

elbow, 1' vertical pipe, 90

°

elbow)

60" min.

60" max.

72" min.

84" max.

89" min.

20' max.

Note: This configuration for use with
corner installation.

Horizontal Termination
Configurations

Figures 26 through 28, and Figure 29 on
page 14 show different configurations for
venting with horizontal termination. Each
figure includes a chart with vertical mini-
mum/maximum and horizontal maximum
dimensions which must be met. Seal all
connections with high temperature silicone
sealant (outer pipe only) as specified in the
second warning statement on page 10. All
horizontal terminations require 1/4" rise per
12" of horizontal run.

Horizontal Venting

Vertical (V)

Horizontal (H)

30" min.

17" max.

UP

UP

UP

Venting with Two 90

°

Elbows

Vertical (V)

Horizontal (H

1

)

Horizontal (H

1

) +

Horizontal (H

2

)

5' min.

2' max.

6' max.

6' min.

4' max.

12' max.

7' min.

6' max.

18' max.

8' min.

8' min.

20' max.

20' max.

8' max.

20' max.

Figure 28 - Horizontal Termination Configuration for Rigid Venting Using Two 90

°

Elbows

Continued