Appendix E

Operator

’s Guide

RJS, Minneapolis, MN

002-5564

Display of Code 128
The Inspector display can accommodate up to 16
characters. However, in order to display symbols great-
er than 16 (maximum of 64), press Select to display the
additional characters.

The encoded data occupies 2 rows on the LCD and is
encoded in a columnar display with one character above
the other.

The first character (column) displays the subset (*A

= Subset A).

The last character is a stop code (**).

The second from the last is a mod 103 check char-

acter.

Double characters beginning with alphanumeric char-

acters designate non-printable control codes applica-
ble to all subsets.

Double numeric characters designate the com-

pressed digit mode in subset C only.

Single characters will always be displayed on the

lower row and are applicable to only subsets A and
B (normal printable characters).

Start Code

Subset A

Char B

(Table

A-1)

Control

Code

Carriage

return

(Table

A-1)

Shift to

subset

C

(Table

A-1)

Digits

3 and 4

(Table

C-3)

Stop

Code

(Table

C-3)

*

C

L

C

1

3

?

*

A

A

B

3

R

F

C

2

4

?

*


Char A

(Table

A-1)

Digit 3
(Table

A-1)

Cntl Code
Line Feed

(Table

A-1)

Digits 1

and 2

(Table

C-3)

Calculated

mod check

Example: