Appendix D

Operator

’s Guide

RJS, Minneapolis, MN

002-5564

Appendix D (Quiet Zone Analysis)

Quiet Zone Analysis
The RJS Inspector D4000 trims data gathered during a
scan to approximately 10 times the X dimension on each
side of a bar code for all symbologies except UPC and
EAN. The areas are assumed to be quiet zones and are
included in the symbol analysis. If a low reflectance
object is detected in these areas, an Overall Symbol
Grade of F will result. The Defects calculation will be the
cause of the F grade and typically be a value greater
than 50%.

Symbols should be scanned in both directions since the
RJS Inspector D4000 is designed to be bi-directional.

Quiet Zone Analysis for UPC and EAN symbols are
described in the following tables. In cases where an
addendum is included in the bar code, an addendum gap
analysis is also performed.

Table D-1 (Acceptable Parameters for Symbols Without
Addendums)

Symbology

Leading QZ

Trailing QZ

UPC-A

9X Minimum

9X Minimum

UPC-E

9X Minimum

7X Minimum

EAN-13

11X Minimum

7X Minimum

EAN-8

7X Minimum

7X Minimum

Table D-2 (Acceptable Parameters for Symbols With
Addendums)

Symbology

Leading QZ

Trailing QZ

GAP Size

UPC-A

9X Minimum

5X Minimum

9 - 12X

UPC-3

9X Minimum

5X Minimum

9 - 12X

EAN-13

11X Minimum

5X Minimum

7 - 10X

EAN-8

7X Minimum

5X Minimum

7 - 10X