Cable Length

15m

5m

Protection Grade

IP67

SER510R/T Communication Protocol

1. SER510R/T adopts standard DB9 interface, with serial asynchronous communication

mode, baud rate is 9600, start bits is 1, data bits is 8, 1 stop bits is 1, no parity bit.

Pin Description: 2------->TXD

3<-------RXD

5<-----> GND

7------->VDD+5V

2. Data protocols, the sensor will send the brightness and temperature that collected

every second, the formats are as follows:

Header (12 bytes)

Effective

Brightness

Brightness

Effective

Temperature

Temperature

Checksum

E5 B2 41 FF 02 00 0A

00 73 6E 72 3A

1 byte

2 bytes

1 byte

2 bytes

2 bytes

Header is for fixed 12 bytes

Effective Brightness: 01: Effective brightness

00: Invalid brightness

Brightness: High byte front, low byte behind, attenuation coefficient of the cover is about

3.3.

Maximum value of brightness: FFFE, and FFFF means brightness is overflow.

The brightness value of the sensors return multiplied by 3.3 is the current unique

degree of brightness (lx).

Effective Temperature: 01: Effective temperature

00: Invalid temperature

Temperature: High byte front, low byte behind. Integer part of temperature is divide the

value by 10, and the decimal part is remainder. The highest bit is 1 when the temperature

is below zero, and the unit of the temperature is Celsius degrees.

Checksum: Including all the header bytes plus 1.

Data example:

E5B2 41FF0200 0A00736E 723A0107 C6010136 8AFA

E5B2 41FF0200 0A00736E 723A0107 5C010133 F7FA