No output in large screen, Confirm if there are any input singles, Confirm if single output – RGBLink VSP 3600 User Manual User Manual
Page 124: Large screen output flash point, Confirm if preview output is normal, Large screen only display part of the image, Signal need to scale, Common questions and solution

7. Common Questions and Solution
VSP 3600 User Manual 124
Confirm if there are any input singles
Press 【MENU】to find "Device information" , check if the INPUT signal is
normal via 【 NEXT 】, if suggest "NO INPUT", means no signal. Check
the front-end signal line, please note do double show or expand for
computer. Can enter other formats signal to do the same operation.
Confirm if single output
Find a belt VGA input (best for DVI) display, connect to the corresponding
output port of processor, check whether the signal is correct on the
monitor. If not display properly, please check whether there is input signal,
or if input wire interface is taken tight, output wire interface is picked up
tightly. If display normally, check if sending card is normally working or
need to replace sending card test.
Large Screen Output Flash Point
Confirm if preview output is normal
Find a belt VGA input (best for DVI) display, connect to the corresponding
output port of processor, check whether the signal is correct on the
monitor. If display normally shows and no flash point, please check
whether DVI outlets put tight or replace to DVI line of sending card. If
display flash point, please judge if input signal, wire, and interface is
normal.
Large Screen only Display Part of the
Signal need to scale
Press 【Scale】, rotate the knob to adjust the size of screen size, including