8
SPLIT is used when multiple VENUS X1 are used in cascade mode. When do cascade, connect the
signals to the signal distributor first, and then connect from the outputs of the signal distributor to each
input of VENUS X1. The operations are as follows:
Push the [SPLIT] button, the button LED light will turn on, and enter to the split function menus. Turn the
knob to choose the split mode, there are two split modes, fixed split and normal split.
FIXED SPLIT: Menus are as follows:
SPLIT: Split function, can choose
“ON” or “OFF”. System default “OFF”.
HORIZONTAL SPLIT: Horizontal fixed split, choose it and push the number button to set the total
horizontal screen number.
VERTICAL SPLIT: Vertical fixed split, choose it and push the number button to set the total vertical
screen number.
SPLIT INDEX: Use can choose the split index, and the LED screen will show the corresponding image.
NORMAL SPLIT: For normal split, user should enable the split function, that is, turn the knob, and set
the
the sub menus:
H TOTAL: LED screen Horizontal total size.
V TOTAL: LED screen Vertical total size.
H POS: This device display image Horizontal size.
V POS: This device display image Vertical size.
H SIZE: This device display image Width setting.
V SIZE: This device display image Height setting.
RESET: If image quality distorts by improper operation, it can be recover by reset.
Save the parameters after setting.