beautypg.com

Climatic region: -10°c, Climatic region: -12°c, Climatic region: -14°c – REMKO CMF-120-1P User Manual

Page 57: Climatic region: -16°c

background image

Climatic region: -10°C

Existing buildings with hot-water heating (share 18%)

Type

COP

Annual performance number with inlet/outlet tem-

perature differential: 7K and inlet temperature...

Annual performance number with inlet/outlet tem-

perature differential: 10K and inlet temperature...

A-7/W35

A2/W35

A10/W35

30°C

35°C

40°C

45°C

50°C

55°C

CMF/CMT 120-1P

2,5

3,9

4,4

4,44

4,30

4,16

4,11

3,96

3,80

CMF/CMT 160-1P

2,6

3,9

4,7

4,52

4,37

4,23

4,18

4,03

3,87

New construction with hot-water heating (share 18%)

Type

COP

Annual performance number with inlet/outlet tem-

perature differential: 7K and inlet temperature...

Annual performance number with inlet/outlet tem-

perature differential: 10K and inlet temperature...

A-7/W35

A2/W35

A10/W35

30°C

35°C

40°C

45°C

50°C

55°C

CMF/CMT 120-1P

2,5

3,9

4,4

4,34

4,20

4,05

4,00

3,85

3,69

CMF/CMT 160-1P

2,6

3,9

4,7

4,40

4,25

4,10

4,05

3,90

3,74

Climatic region: -12°C

Existing buildings with hot-water heating (share 18%)

Type

COP

Annual performance number with inlet/outlet tem-

perature differential: 7K and inlet temperature...

Annual performance number with inlet/outlet tem-

perature differential: 10K and inlet temperature...

A-7/W35

A2/W35

A10/W35

30°C

35°C

40°C

45°C

50°C

55°C

CMF/CMT 120-1P

2,5

3,9

4,4

4,34

4,20

4,06

4,01

3,87

3,72

CMF/CMT 160-1P

2,6

3,9

4,7

4,41

4,27

4,13

4,08

3,94

3,79

New construction with hot-water heating (share 18%)

Type

COP

Annual performance number with inlet/outlet tem-

perature differential: 7K and inlet temperature...

Annual performance number with inlet/outlet tem-

perature differential: 10K and inlet temperature...

A-7/W35

A2/W35

A10/W35

30°C

35°C

40°C

45°C

50°C

55°C

CMF/CMT 120-1P

2,5

3,9

4,4

4,24

4,10

3,95

3,91

3,76

3,61

CMF/CMT 160-1P

2,6

3,9

4,7

4,29

4,15

4,00

3,95

3,81

3,65

Climatic region: -14°C

Existing buildings with hot-water heating (share 18%)

Type

COP

Annual performance number with inlet/outlet tem-

perature differential: 7K and inlet temperature...

Annual performance number with inlet/outlet tem-

perature differential: 10K and inlet temperature...

A-7/W35

A2/W35

A10/W35

30°C

35°C

40°C

45°C

50°C

55°C

CMF/CMT 120-1P

2,5

3,9

4,4

4,27

4,13

4,00

3,96

3,72

3,68

CMF/CMT 160-1P

2,6

3,9

4,7

4,34

4,20

4,07

4,03

3,88

3,74

New construction with hot-water heating (share 18%)

Type

COP

Annual performance number with inlet/outlet tem-

perature differential: 7K and inlet temperature...

Annual performance number with inlet/outlet tem-

perature differential: 10K and inlet temperature...

A-7/W35

A2/W35

A10/W35

30°C

35°C

40°C

45°C

50°C

55°C

CMF/CMT 120-1P

2,5

3,9

4,4

4,17

4,03

3,89

3,85

3,71

3,56

CMF/CMT 160-1P

2,6

3,9

4,7

4,22

4,08

3,94

3,90

3,75

3,61

Climatic region: -16°C

Existing buildings with hot-water heating (share 18%)

Type

COP

Annual performance number with inlet/outlet tem-

perature differential: 7K and inlet temperature...

Annual performance number with inlet/outlet tem-

perature differential: 10K and inlet temperature...

A-7/W35

A2/W35

A10/W35

30°C

35°C

40°C

45°C

50°C

55°C

CMF/CMT 120-1P

2,5

3,9

4,4

4,14

4,01

3,88

3,84

3,71

3,57

CMF/CMT 160-1P

2,6

3,9

4,7

4,22

4,08

3,95

3,92

3,78

3,64

New construction with hot-water heating (share 18%)

Type

COP

Annual performance number with inlet/outlet tem-

perature differential: 7K and inlet temperature...

Annual performance number with inlet/outlet tem-

perature differential: 10K and inlet temperature...

A-7/W35

A2/W35

A10/W35

30°C

35°C

40°C

45°C

50°C

55°C

CMF/CMT 120-1P

2,5

3,9

4,4

4,02

3,89

3,76

3,72

3,58

3,44

CMF/CMT 160-1P

2,6

3,9

4,7

4,08

3,95

3,82

3,77

3,64

3,49

Note: A differential of 7K has a standard floor-heating layout, a differential of 10K is typical for a radiator system

Additional key data: a heating-threshold temperature of 15°C for old construction and 12°C in new construction, a differential at the condenser

(test-bench measurements: 5K)

Annual performance number for CMF/CMT 120-1P / CMF/CMT 160-1P