Remko cmf / cmt – REMKO CMF-120-1P User Manual
Page 14
![background image](https://www.manualsdir.com/files/802493/content/doc014.png)
REMKO CMF / CMT
Ö
Outdoor unit CMT 160-1P
Indoor unit
CMT 160-1P
Fan
Outdoor area
Refrigerant lines
3
/
8
" and
5
/
8
"
Mains cable
Indoor unit
(3x1.5mm
2
)
Indoor area
condensate drain
(must be designed to be frost proof!)
* Mains supply
230V/1~50Hz 32A
(3x6 mm
2
)
Control cable (4x1 mm
2
)
Outdoor unit CMF 160-1P
Fan
condensate drain
(must be designed to be frost proof!)
Hot-water supply
and return pipes
(DN 25)
Mains cable
Electric booster
heater
3x(5x1.5 mm
2
)
Mains cable
Indoor unit
(3x1.5mm
2
)
Mains cable
Electric booster
heater (optional)
3x(5x1.5 mm
2
)
condensate drain
Refrigerant lines
3
/
8
" and
5
/
8
"
Control cable (4x1 mm
2
)
* Mains supply
230V/1~50Hz 32A
(3x6 mm
2
)
Inlet for
Heating (DN 25)
Common
Return pipe (DN 25)
Supply pipe for hot-
water tank (DN 25)
Indoor unit
CMF 160-1P
System Layout CMF 160-1P / CMT 160-1P
14