Remko wkf duo – REMKO WKF 120 Duo User Manual
Page 48

Outdoor unit error display
1
Fig. 46: Display on WKF 120/180 Duo outdoor units
1: Display
Display
LED display
Replac
e
Meaning
Red
Green
Yellow
101
l
Z
m
IM, AM F1/F2 twisted
121
IM
Indoor temperature probe defective/short-circuited
(CN41)
162
IM
EEPROM error
201
l
Z
m
IM, AM Board communications errors. Incorrect com kit board
202
l
l
m
IM, AM Interruption in communication between AM and IM
203
l
l
Z
AM
No communication between motherboard and inverter
board for 1 min.
221
l
Z
m
AM
Error in outside temperature probe
231
l
Z
m
AM
Evaporator probe error
251
l
Z
m
AM
Hot gas temperature probe error
320
l
Z
m
AM
Overload switch probe error
403
l
Z
m
AM
Ice protection compressor (in cooling mode only)
404
l
Z
m
AM
Safety operation after compressor overload
(normal operation)
416
l
Z
m
AM
Compressor overheated
419
l
Z
m
AM
Malfunction of electronic expansion valve
425
l
Z
m
AM
Phase error malfunction. A phase conductor is missing
(WKF 180 only)
440
l
Z
m
AM
BLDC fan 1 error
441
l
Z
m
AM
BLDC fan 2 error
443
l
Z
m
AM
Gas leakage error (before operation)
458
m
m
l
AM
Compressor start error
461
m
Z
m
AM
Compressor, board
462
l
Z
m
AM
Current consumption is too high
463
l
Z
m
AM
Compressor overload switch (OLP) is triggered
464
Z
m
m
AM
Inverter board current consumption IPM is too high
465
m
l
Z
AM
Compressor current consumption too high
REMKO WKF Duo
48