background image

Adding refrigerant

DANGER!

The connection of refrigerant pipes and the

handling of refrigerant may be only be carried

out by qualified personnel (competence cate-

gory I).

DANGER!

Only refrigerant in a liquid state may be used to

fill the cooling cycle!

CAUTION!

Danger of injury from refrigerant!

Refrigerant degreases the skin on contact and

may cause cold burns.

Therefore:

- Wear chemical-resistant protective gloves

when undertaking any work involving refriger-

ants.

-Safety glasses must be worn to protect the

eyes.

NOTICE!

Check the overheating to determine the refrig-

erant fill quantity.

n

The outdoor unit is pre-filled with refrigerant

sufficient for a length of ordinary pipe up to 10

metres.

n

If the length of any of the pipelines exceeds 10

metres, then an additional filling for each addi-

tional metre of pipe length (basic length) is

required.

Basic

pipe length

Additional fill quantity

WKF 120

Duo

WKF 180

Duo

Up to and incl.

10m

0 g/m

0 g/m

Basic

pipe length

Additional fill quantity

WKF 120

Duo

WKF 180

Duo

10m to max. 50m

per circuit

50 g/m

---

10m to max. 75

m per circuit

---

50 g/m

Examples

Basic

pipe length

Additional fill quantity

WKF 120/180 Duo

10 m

0 g

15 m

250 g

20 m

500 g

25 m

750 g

NOTICE!

The escape of refrigerant contributes to cli-

matic change. In the event of escape, refrig-

erant with a low greenhouse potential has a

lesser impact on global warming than those

with a high greenhouse potential. This device

contains refrigerant with a greenhouse poten-

tial of 1975. That means the escape of 1 kg of

this refrigerant has an effect on global warming
that is 1975 times greater than 1 kg CO

2

,

based on 100 years. Do not conduct any work

on the refrigerant circuit or dismantle the

device - always enlist the help of qualified

experts.

43