Remko wkf duo, At hl, Nf n-max – REMKO WKF 120 Duo User Manual
Page 18: At c o p, Heating capacity at an inlet temperature of 55 °c

Heating capacity at an inlet temperature of 55 °C
[°C]
[k
W
]
AT
HL
0,0
5,0
10,0
15,0
20,0
25,0
30,0
35,0
40,0
-16
-14
-12
-10
-8
-6
-4
-2
0
2
4
6
8
10
12
14
16
18
20
NF
n-max
Fig. 15: Heating capacity WKF 180 Duo at an inlet temperature of 55 °C
AT: Outside temperature / HL: Heating capacity
NF: Rated frequency / n-max: max. frequency
COP at inlet temperature 35°C, 45°C and 55°C
[°C]
AT
C
O
P
[-]
0
1
2
3
4
5
6
-15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
VL
35° C
VL
45° C
VL
55° C
Fig. 16: COP WKF 180 Duo at inlet temperature 35°C, 45°C and 55°C
AT: Outside temperature
VL: Inlet temperature
REMKO WKF Duo
18
This manual is related to the following products: