System description, Transportation and packaging – REMKO BL 261 User Manual
Page 5
The BL 261 and BL 351 room air
conditioning units have a REMKO
BL...AT outdoor component as
well as a BL...IT indoor unit.
The outdoor component serves to
output the heat extracted by the
indoor unit from the room being
cooled.
In heater operation, the heat taken
up by the outdoor unit can be
discharged by the indoor unit into
the room to be heated.
The outdoor component can be
installed outdoors or indoors.
The latter requires the fulfilment of
certain conditions. The indoor unit
is designed to be mounted high up
on indoor walls. It is operated by
an infrared remote control.
The outdoor component consists of
a cooling circuit with compressor,
fin condenser, condenser fan,
reverse flow valve, quick-release
couplings and throttle element.
The outdoor component is
controlled by the controller in the
indoor unit.
The indoor unit consists of a fin
vaporiser, vaporiser fan, controller
and condensation tray.
Floor consoles, wall consoles and
condensation pumps are available
as accessories.
System description
The units are delivered in strong
transport packaging. Immediately
check the units on delivery and
make a note of any damage or
missing parts on the delivery note.
Inform the forwarding agent and
contractual partner.
No warranty can be assumed for
later claims.
Transportation and
packaging
Cooling circuit diagram for indoor unit
Vaporiser fan
Suction line connection
with quick-release coupling
Injection pipe connection
with quick-release coupling
Vaporiser
The connection between the indoor unit and outdoor component is effected
using the factory-supplied refrigerant pipes by means of quick-release couplings.
Outdoor component
System configuration
Injection pipe
Indoor unit
Indoor area
Outdoor area
Shut-off valve with
quick-release coupling
Condenser fan
Condensate line
Suction line
Condensate line
Control cable
Mains cable
M
M
Cooling circuit diagram for the outdoor component
Condenser fan
Quick-release
coupling
connection valve
Suction line
Quick-release
coupling
connection valve
Injection pipe
Compressor
Capillary tube throttle element
Filter dryer
Condenser
Reverse flow valve
Connection for
pressure gauge
5