Remko bl, Electrical connection diagram – REMKO BL 261 User Manual
Page 22
Neutral conductor
Fan motor (white)
■
Control cables should be
screened if laid in areas exposed
to strong magnetic fields.
■
Details concerning the electrical
protection of the system are
provided in the technical data.
Connection of the outdoor
component
Proceed as follows to connect the
cable:
1. Remove the cover from the
unit.
2. Remove the side panel next to
the terminals.
3. Feed the control cable through
the edge protection rings on
the fixed connection panel.
5. Insert the connector into the
corresponding socket.
6. Anchor the cable in the strain
relief and re-assemble the unit
(figure 12)
.
Check all plugged and clamped
terminals to verify they are
seated correctly and make
a permanent contact. Tighten
as required.
!
ATTENTION
12
Connection of the outdoor component
Connecting the indoor unit
2 a 10 m long control cable are
already connected to the indoor
unit. These control cables must be
laid to the outdoor component and
connected to the terminal block.
Electrical connection diagram
Connection of BL 261, BL 351
11
Connection of the indoor unit
Front terminal for
control cable to outdoor
component
Cover
Rear terminal for
electrical supply
Cover
Outdoor component
Indoor unit
Mains cable
Reverse flow valve (black)
230 V~,
50 Hz,
L1 / N
/ PE
Compressor contact (red)
PE
N
N
PE
3
2
3
PE
N
L
L
L
2
1
1
Exterior conductor
rear
terminal
front
terminal
REMKO BL
22