Remko bl – REMKO BL 261 User Manual
Page 10
HEATING mode
In heating mode, you can heat the room in spring or autumn. The
selected room temperature is set with the
▲/▼ keys in 1°C increments.
If the room temperature is 1°C below the selected target temperature,
the indoor unit will start to heat the air in the room. If the set room
temperature is exceeded by approx. 1°C, the controller will switch off
heating mode. To protect the compressor, the controller will wait 3
minutes before switching on the heating mode again.
MODE
HEATING MODE
In dehumidification mode, the target temperature is set to 24°C. Due to
the low temperature of the refrigerant, the temperature of the air at the
condenser falls below the dew point. The excess moisture in the air is
condensed by the vaporiser, the room is dehumidified. The fan speed
is permanently set to the lowest setting in order to achieve a maximum
level of dehumidification. The compressor switches on and off in intervals
between 17°C and 24°C.
DEHUMIDIFICATION MODE
DEHUMIDIFICATION
MODE
MODE
The fan speed can be adjusted with this key. A selection can be made
between low, medium, high and automatic fan speed.
FAN Key
FAN
FAN
FAN
FAN
The air discharge fins are individually adjusted with this key.
A selection can be made between 5 positions and an oscillating function.
FINS Key
The oscillating function of the air fins can be adjusted with this key.
This makes it possible to switch directly between a preset position and
the oscillating function. The air distribution in the room is improved with
the swing function.
SWING key
SWING
SWING
SWING
REMKO BL
10