beautypg.com

REMKO BL 261 User Manual

Page 13

background image

Maintenance

It is recommended that you
take out a maintenance
contract with an annual service
from an appropriate specialist
firm.

Cleaning of condensation
pump (optional equipment)

An optional integrated or separate
condensation pump may be in the
indoor unit, which pumps out any
accumulated condensation into
higher positioned drains.
Observe the care and maintenance
instructions in the separate
Operating Instructions.

Type of task

Checks/Maintenance/Inspection

Commissioning

Monthly

Half-yearly

Yearly

General

Measure voltage and current

Check function of compressor/fans

Check function of fan

Dirt on condenser/vaporiser

Check refrigerant fill quantity

Check condensate drain

Inspect insulation

Check moving parts

Sealing test for cooling circuit

1)

Cleaning the housing on
the indoor unit

1. Disconnect the supply voltage

to the equipment.

2. Open and fold the air inlet

guard on the front side
upwards.

3. Clean the guard and cover with

a soft, damp cloth.

4. Switch the supply voltage back

on.

Air filter for indoor unit

Clean the air filter at intervals of
no more than 2 weeks.
Reduce this interval if the air is
especially dirty.

Cleaning the filter on
the indoor unit

1. Disconnect the supply voltage

to the equipment.

2. Open the front side of the unit

by folding the guard upwards
and allowing it to engage
(figure 1)

.

3. Raise the filter and pull it out

pulling downwards.

2 Cleaning using a vacuum cleaner

3 Cleaning with lukewarm water

This ensures the operational
reliability of your system!

TIP

4. Clean the filter with

a commercially available
vacuum cleaner. Turn the dirty
side upwards (figure 2).

5. Dirt can also be removed

by carefully cleaning with
lukewarm water and mild
cleaning agents. Turn the dirty
side downwards (figure 3).

6. If water is used, let the filter dry

out properly in the air before
fitting it back into the unit.

7. Carefully insert the filter. Ensure

that it locates correctly.

8. Close the front side as

described above in reverse
order.

9. Switch the supply voltage back

on.

10. Switch the unit on again.

1 Fold the guard upwards

13