Appendix b - lumina power driver connections – Quantum Composers LDDC 1550 User Manual
Page 33

33 |
P a g e
Appendix B - Lumina Power Driver Connections
The LDDC/LSC can be interfaced to many of the Lumina Power brand laser diode drivers.
Quantum Composers offers optional cables that can be purchased to interface to these diode
drivers. Below is a table showing the types of cables that can be used to interface with the
drivers.
Lumina Power
Driver Model#
Quantum Composers
Cable Part Number
Special Instructions
LDD-50
LDD-100
LDD-150
LDD-250
LDD-600
LDD-1000
LDD-1500
LDD-2500
LDD-3000
LDD-6000
300002-223 (non-shielded)
300002-229 (shielded)
Pulsed output only available on LDD-
2500/3000/6000 series. For use with the
other LDD models, disable the pulse
control function. This can be turned on/off
on the system setup page #2 or the “PE”
command. The temperature interlock must
be bypassed as on the setup page #2 or the
“TB” command. LDDC/LSC can be
powered from LDD driver.
LDDHC-600
LDDHC-1000
LDDHC-1500
300002-223 (non-shielded)
300002-229 (shielded)
The temperature interlock must be
bypassed as on the setup page #2 or the
“TB” command. LDDC/LSC can be
powered from LDD driver.
LDQCW-50
300002-223 (non-shielded)
300002-229 (shielded)
The temperature interlock is not utilized
and can be bypassed as on the setup page
#2 or the “TB” command. The LDDC/LSC
must be powered from the external wall
mount supply.
LDQCW-250
LDQCW-600
300002-224
The LDDC/LSC can be powered from the
250/600W drivers. The poor load match
and ready status are not currently
monitored by the LDDC/LSC.
LDY-600
LDY-1000
LDY-1500
300002-223 (non-shielded)
300002-229 (shielded)
The LDDC/LSC may be powered directly
from the LDY.
LDYHC-600
LDYHC-1000
LDYHC-1500
300002-223 (non-shielded)
300002-229 (shielded)
The LDDC/LSC may be powered directly
from the LDYHC.