Rs-232 provisioner commands – Olson Technology OTEB-CW-B User Manual
Page 39
36
RS-232 Provisioner Commands
RS-232 Command
Code
Units
Notes
Set Control Mode to APC
SMPC
-
Sets the control mode of the unit to Power Control.
Set Control Mode to AGC
SMGC
-
Sets the control mode of the unit to Gain Control.
Set Control mode to ACC
SMCC
-
Sets the control mode of the unit Current Control.
Set Output Power Setpoint
SOP
dBm
Sets the APC mode setpoint.
Set Gain Control Setpoint
SGS
dB
Sets the AGC mode setpoint.
Set Current Control Setpoint
SLC
Amps
Sets the ACC mode setpoint.
Set “Input Power Low” alarm level
SPINLOW
dBm
Sets the threshold level for the “Input power Low” alarm. Overrides the
factory default setting.
Read Factory Default “Input Power Low”
Alarm Level.
RFDPINLOW
dBm
Reads the factory default setting for the “Input Power Low” alarm level.
Restore access level to user mode.
LOGOUT
-
Disables access to the provisioning commands.
Change the access pass code for the pro-
visioning commands.
PASSCODE
-
Sets the new passcode. The passcode must be a 6 digit number.
Default Value is 999999
Restore all parameters to their factory
defaults.
RESTORE -
Set Relay “Input Power Low” Alarm Status.
SRAPINLOW
See
Note
Enables or disables activation of the relay for the alarm
0 Disables the alarm, 1 Enables the alarm.
Set Relay “Input Power High” Alarm Status.
SRAPINHIGH
See
Note
Enables or disables activation of the relay for the alarm
0 Disables the alarm, 1 Enables the alarm.
Set Relay “Input Power Too High” Alarm
Status.
SRAPINTOOHIGH See
Note
Enables or disables activation of the relay for the alarm
0 Disables the alarm, 1 Enables the alarm.
Set Relay “Output Power Low” Alarm
Status.
SRAPOUTLOW See
Note
Enables or disables activation of the relay for the alarm
0 Disables the alarm, 1 Enables the alarm.
Set Relay “Output Power High” Alarm
Status.
SRAPOUTHIGH See
Note
Enables or disables activation of the relay for the alarm
0 Disables the alarm, 1 Enables the alarm.
Set Relay “Output Power Too High” Alarm
Status.
SRAPOUTTOOHIGH See
Note
Enables or disables activation of the relay for the alarm
0 Disables the alarm, 1 Enables the alarm.
Set Relay “Fan Failure: Alarm Status
SRAFAN
See
Note
Enables or disables activation of the relay for the alarm
0 Disables the alarm, 1 Enables the alarm.
Set Laser “Ambient Temperature High”
Alarm Status.
SRATEMP See
Note
Enables or disables activation of the relay for the alarm
0 Disables the alarm, 1 Enables the alarm.
Set Minimum Current Adjust when in ACC
Mode
SACCNUDGEMIN
Amps
Sets the minimum current that can be adjusted from the front panel inter-
face using the minor adjust feature when the unit is in ACC mode. Over-
rides the factory setting.
Set Maximum Current Adjust when in ACC
Mode
SACCNUDGEMAX
Amps
Sets the maximum current that can be adjusted from the front panel inter-
face using the minor adjust feature when the unit is in ACC mode. Over-
rides the factory setting.
Set Minimum Power Adjust when in APC
Mode
SAPCNUDGEMIN
dBm
Sets the minimum output power that can be adjusted from the front panel
interface using the minor adjust feature when the unit is in APC mode.
Overrides the factory setting.
Set Maximum Power Adjust when in APC
Mode
SAPCNUDGEMAX
dBm
Sets the maximum output power that can be adjusted from the front panel
interface using the minor adjust feature when the unit is in APC mode.
Overrides the factory setting.
Set Minimum Gain Adjust when in AGC
Mode
SAGCNUDGEMIN
dB
Sets the minimum gain that can be adjusted from the front panel interface
using the minor adjust feature when the unit is in AGC mode. Overrides the
factory setting.
Set Maximum Gain Adjust when in AGC
Mode
SAGCNUDGEMAX
dB
Sets the maximum gain that can be adjusted from the front panel interface
using the minor adjust feature when the unit is in AGC mode. Overrides the
factory setting.