25

isolate any problems of the deployment that are not related to video
equipment and/or the EDFA’s active optical performance.

iii.

For non-CWDM EDFA models

i. Next connect the Output C ports (SC/APC/Green) to the installation site

downstream fibers (to the premise).

iv.

For all EDFA Models: Once all CWDM and output port connections have
been made then:

i. Connect the installation sites 1550nm (C-Band) video feed to the

(SC/APC/Green) Input C port of the EDFA unit.

ii. (Optionally) Connect monitoring equipment (power meter, CATV detec-

tor) to the 1550nm (C-Band) amplifier output monitor port of the EDFA
unit. See specification document for monitor port output power (typically
much lower output power level than the main output ports).

v.

Proceed to next section