Applies to models with front panel lcd only – Olson Technology OTEB-CW-B User Manual
Page 38
35
RS-232 Command
Code
Units
Notes
Bit 9 - Input Off Alarm
Bit 10 - Interlock
Bit 11 - Power Supply 1 Failed Alarm
Bit 12 - Power Supply 2 Failed Alarm
Bit 13 - Reserved
Bit 14 - Emission On
Bits 15 - 31 are reserved.
Read Relay Alarm Status
RRAS
-
Returns the alarms that are assigned to trip the alarm relay.
Read Relay Status
RRS
-
Returns the state of the relay “Normal” or “Tripped”
Read Alarm Status
RAL
-
Returns the individual alarm conditions within the Laser.
Read “Output Power High” Alarm Level
RPOUTHIGH
dBm
Returns: “Pout High Alarm Level = xx.x”
NOTE: this value could be negative and/or have 2 digits containing 1 deci-
mal point; i.e. –12, -2.2, 0.0, 3.5
Read “Output Power Too High” Alarm
Level
RPOUTTOOHIGH
dBm
Returns: “Pout Too High Alarm Level = xx.x
NOTE: this value could be negative and/or have 2 digits containing 1 deci-
mal point; i.e. –12, -2.2, 0.0, 3.5
Read Minimum Current Adjust when in
ACC Mode
RACCNUDGEMIN
Amps
*Returns “ACCNudgeMin = x.xxx”
Read Maximum Current Adjust when in
ACC Mode
RACCNUDGEMAX
Amps
*Returns “ACCNudgeMax = x.xxx”
Read Current Adjust Step Size when in
ACC Mode
RACCNUDGESTEP
Amps
*Returns “ACCNudgeStep = x.xxx”
Read Minimum Power Adjust when in APC
Mode
RAPCNUDGEMIN
dBm
*Returns “APCNudgeMin = xx.x dBm”
Read Maximum Power Adjust when in APC
Mode
RAPCNUDGEMAX
dBm
*Returns “APCNudgeMax = xx.x dBm”
Read Power Adjust Step Size when in APC
Mode
RAPCNUDGESTEP
dB
Returns “APCNudgeStep = xx.x dBm”
Read Minimum Gain Adjust when in AGC
Mode
RAGCNUDGEMIN
dB
Returns “AGCNudgeMin = xx.x”
Read Maximum Gain Adjust when in AGC
Mode
RAGCNUDGEMAX
dB
Returns “AGCNudgeMax = xx.x”
Read Gain Adjust Step Size when in AGC
Mode
RAGCNUDGESTEP
dB
Returns “AGCNudgeStep = xx.x”
Read Default Minimum Current Adjust
when in ACC Mode
RFDACCNUDGEMIN
Amps
Returns “FD ACCNudgeMin = x.xxx”
Read Default Maximum Current Adjust
when in ACC Mode
RFDACCNUDGEMAX
Amps
*Returns “FD ACCNudgeMax = x.xxx”
Read Default Minimum Power Adjust when
in APC Mode
RFDAPCNUDGEMIN
dBm
*Returns “FD APCNudgeMin = xx.x dBm”
Read Default Maximum Power Adjust
when in APC Mode
RFDAPCNUDGEMAX
dBm
*Returns “FD APCNudgeMax = xx.x dBm”
Read Default Minimum Gain Adjust when
in AGC Mode
RFDAGCNUDGEMIN
dB
*Returns “FD AGCNudgeMin = xx.x”
Read Default Maximum Gain Adjust when
in AGC Mode
RFDAGCNUDGEMAX
dB
*Returns “FD AGCNudgeMax = xx.x”
*= Applies to models with front panel LCD Only