LED Status Indication

1. LED Status Table

LED Color

Alarm

Other

Indication

Condition

All LED’s

Green

None

Data or Voice failure but Video

OK

Some Blue ports have weak or no signal output

and no EDFA alarm-Video not affected

All LED’s

Green

None

Weak or no video signal to entire

neighborhood fed off that port

Some Green Ports have weak or no output - no

EDFA Alarm but Data/voice affected on same ports

48V Sup

Red

Major

no other LED’s affected

Blown Fuse

48V Sup

Amber

Minor

no other LED’s affected

48V Power Supply Feed Missing

48V

Sup Green None

-

-

Equip

Red

Major

no other front panel LED’s af-

fected, Power Supply LED not

on

Power Supply unit has failed or is unplugged

Equip

Amber

minor

no other LED’s affected

Temp alarm active

Mode

Amber

Major

Equip-Red

Interlock Connection open

Mode

Amber

Minor

no other LED’s affected

Key-switch is off

Pwr In

Red

Major

Mode-Red, Equip-Red

Optical Input Failure

Pwr In

Amber

Minor

Equip-Amber

Optical Input below or above threshold

Pwr In

Green

None

-

-

Pwr Out

Amber

Minor

Equip-Amber

Output optical Power is below or above preset

threshold alarm

Pwr Out

Red

Major

Equip-Red, Mode-Amber

Optical Output has fallen below critical levels and

has been shut off

Fan

Red

Major

Red Fan LED Lit and Red

Equipment LED

Fan or Airflow failure

Pump

Red

Minor

No other LED indications

Pump Current below or above thresholds

2. Minor Alarms

When present the laser emission remains ON. An alarm message is displayed on the front
panel, and the Minor Alarm indicator is illuminated. Minor Alarm conditions will reset auto-
matically when operating conditions are within the design threshold.

3. Major Alarms

When present the laser emission is turned OFF. An alarm message is displayed on the
front panel, the Major Alarm indicator is lit steady and the Alarm relay contacts on the rear
panel are deactivated. In normal operation the relay is energized.

Major Alarms will reset and emission will resume if the alarm condition is corrected. The
exception is the “Output Power Off” Major alarm which requires the emission key to be cy-
cled to regain amplifier operation.