Led status indication, Led status table – Olson Technology OTEB-CW-B User Manual
Page 36
33
LED Status Indication
1. LED Status Table
LED Color
Alarm
Other
Indication
Condition
All LED’s
Green
None
Data or Voice failure but Video
OK
Some Blue ports have weak or no signal output
and no EDFA alarm-Video not affected
All LED’s
Green
None
Weak or no video signal to entire
neighborhood fed off that port
Some Green Ports have weak or no output - no
EDFA Alarm but Data/voice affected on same ports
48V Sup
Red
Major
no other LED’s affected
Blown Fuse
48V Sup
Amber
Minor
no other LED’s affected
48V Power Supply Feed Missing
48V
Sup Green None
-
-
Equip
Red
Major
no other front panel LED’s af-
fected, Power Supply LED not
on
Power Supply unit has failed or is unplugged
Equip
Amber
minor
no other LED’s affected
Temp alarm active
Mode
Amber
Major
Equip-Red
Interlock Connection open
Mode
Amber
Minor
no other LED’s affected
Key-switch is off
Pwr In
Red
Major
Mode-Red, Equip-Red
Optical Input Failure
Pwr In
Amber
Minor
Equip-Amber
Optical Input below or above threshold
Pwr In
Green
None
-
-
Pwr Out
Amber
Minor
Equip-Amber
Output optical Power is below or above preset
threshold alarm
Pwr Out
Red
Major
Equip-Red, Mode-Amber
Optical Output has fallen below critical levels and
has been shut off
Fan
Red
Major
Red Fan LED Lit and Red
Equipment LED
Fan or Airflow failure
Pump
Red
Minor
No other LED indications
Pump Current below or above thresholds
2. Minor Alarms
When present the laser emission remains ON. An alarm message is displayed on the front
panel, and the Minor Alarm indicator is illuminated. Minor Alarm conditions will reset auto-
matically when operating conditions are within the design threshold.
3. Major Alarms
When present the laser emission is turned OFF. An alarm message is displayed on the
front panel, the Major Alarm indicator is lit steady and the Alarm relay contacts on the rear
panel are deactivated. In normal operation the relay is energized.
Major Alarms will reset and emission will resume if the alarm condition is corrected. The
exception is the “Output Power Off” Major alarm which requires the emission key to be cy-
cled to regain amplifier operation.