3.1.1 Basic System A


The Basic System A consists of a mounting rail, an SynPur, a Synthesizer
cartridge, and the additive. Basic System A is shown in the figure below.

SynPur












Mounting rail

Product

Infeed
















Synthesizing stage

Additive

Figure 2: Basic System A

3.1.2 Basic System B


The Basic System B consists of a mounting rail, an SynPur, two to four synthesizer
cartridges, and the additive. Basic System B is shown in the figure below. The
higher the humidification demand, the faster the resins in the synthesizer cartridges
are depleted. To extend the replacement intervals, up to four cartridges can be
connected in sequence. As shown in the figure, the mounting rail is connected to
the inlet of the first cartridge. The outlet of the first cartridge is connected to the
inlet of the second cartridge, etc. The outlet of the last cartridge is connected again
to the mounting rail.

bar

ba

r

ba

r

bar

IN

OUT

Pat en t ier t e
Re in ra u m -Be fe u ch tu n g

Pr oz es so rg e st eu er t e
De m in er al isi er u ng

Au to m a tis ie rt e

Hy gi en ef u nk ti on e n

M od e m -
Sch n it ts te lle

Au sb e ut e 10 0%

An b in du n g
G eb äu d et ec hn ik

Ein /Au s

Pr o du k t

G as

Sy nt h es e -

w as se r

Sy nt h es e -

p at r o ne

Re in w as se r