Figure 18: Replacing the SynPur

-

Turn off the mains switch (3) and disconnect the plug (4).


-

Remove the two plugs (1) from the device by loosening the knurled ring on the
plug.


-

Shut off the water supply (2) on the mounting rail.

-

Open the shutoff valve (5). Wait until the system is completely depressurized.
The pressure is indicated on the pressure gage.

-

Close the shutoff valve on the CO

2

bottle (6).


-

Release the self-retracting hoses (7) (14/17 open-jawed wrench) and allow to
slide into the container.

-

Remove the SynPur from the support console and set the new device in place.

-

Connect the new device in reverse order.