These assembly instructions relate only to individual systems. For the
customer systems, the manufacturer delivers individual system diagrams. In
addition, instruction on the assemblies will also be provided. Assembly
instructions, diagrams, and the instruction are binding for the design.
-
The material specification must be followed.
4.2.1 Support console SynPur
-
If possible the equipment should be installed in an operating area that is
accessible only to a limited group of people.
-
The ambient temperature must be +10°C and +30°C year-round.
-
The assembly location should be selected such that direct exposure of the
equipment to heat or sunshine is not possible.
IMPORTANT:
The equipment should be mounted on a good bearing wall surface (with a load
capacity of 50 kg).
Through holes 8 mm
Figure 11: Hole pattern, support console
There should be an overhead clearance of 50 cm across the entire width of the
support console, and 20 cm on the left and right side of the console. The bottom
edge of the console should be 1.2 m from the floor.
ATTENTION:
To prevent damage from potential leaks, no electrically conductive parts or goods
should be mounted/placed under the support console.
4.2.2 Mounting rail
-
The assembly site should be selected in such a way that the mounting rail is
always accessible.
-
Direct exposure to heat or sunlight should be avoided.