H*38DF PFC Peninsula Gas Fireplace

Installation

Note: Images are shown without screens for clarity purposes. However,

your fireplace should not be operated without proper installation of

screens.

Figure 8� Flue cover and collar removal, Top Vented fireplace.

Figure 8a� Flue cover and collar installation, Rear Vented fireplace.

Section 3-1:

Converting to Rear Vent

Use the following instructions to convert a H*38PF* for Rear Vent use:

1. Remove the Rear flue cover and gasket (5" and 8") on the flue

outlet, as shown in Figure 8.

2. Next, Remove the Top flue collar's (5" and 8") on the flue outlet,

as shown in Figure 8.

3. Install the (removed) Rear flue cover and gasket material, to the

Top vent outlet. Fasten the cover with included hardware, as

illustrated Figure 8a.

4. Install the (5" and 8") collars to the rear vent outlet using the

included hardware, as illustrated Figure 8a.

Montigo supplies a variety of direct venting and termination options.

The direct vent termination location MUST be selected such that

it is the highest point in the venting assembly� It should also be

selected such that it provides the shortest vent run possible. Should

it be impossible to ensure that the termination is the highest point or

should it be impossible to meet the venting guidelines laid out below

please contact your Montigo dealer to discuss power venting options.

NOTES FOR PLANNING VENTING:

„

Venting can originate from the unit through the top or

through the rear

„

Venting can terminate through the roof or through an
exterior wall
.

„

Refer to Appendix A - Termination Locations to ensure the

planned termination location is acceptable.

„

Once the termination location has been established, refer

to the appropriate section below for installation details

„

All fireplaces shipped from the factory are Top vent.

„

Silicone application is NOT required when joining Montigo

vent pipes and components�

See Section 3-1 for converting the unit from top vent to rear vent�

5” Inner Flue

Cover Plate

8” Outer Flue

Cover Plate

8” Outer

Flue Collar

5” Inner

Flue Collar

Flue Collar

8” Outer

Flue Collar

5” Inner Flue

Cover Plate

Outer Flue

Outer Plate

Section 3: Venting