H*38DF PFC Peninsula Gas Fireplace
Installation
Section 2: Framing
Note: Images are shown without screens for clarity purposes. However,
your fireplace should not be operated without proper installation of
screens.
1).
Frame in the enclosure for the unit with framing materials. The
framed opening for the assembled fireplace is 23 3/4" wide, x 44"
high x 41" deep, see Figure 2
.
NOTE: When constructing the framed opening, please ensure there is
access to install the gas line when the unit is installed. See Figure 21�
Figure 2� Framing dimensions.
Figure 3� Combustible Framing for shelves over the fireplace, Rear vent.
Figure 5� Non Combustible Framing with alcove above fireplace, Top Vent.
41
23 3/4
44
Figure 4� Combustible Framing for shelves over the fireplace, Top vent.
11”
Min.
Combustible Shelf
33”
44”
Exterior
Wall
Combustible Header
12” Max.
4” Nailing flange
or Non-combustible
material.
46” Min
17 1/2”
2” Min.
44”
Combustible Shelf
Combustible Header
Min.
Exterior
Wall
PEL Short
90 elbow
4” Nailing flange
or Non-combustible
material.
58” Min for HP
Floor
39 5/8”
44”
Combustible
Header
Min. 1 ”
2”
Ceiling level
Non-Combustible
Header
Non-Combustible
materials. Alcove
over fireplace.
Top Vent
Non-Combustible
Materials, with Low
profile mantel / Alcove
over fireplace.
84”
min.