H*38DF PFC Peninsula Gas Fireplace

XG0816 - 150204.1

Operation

SIT Proflame 2 Electronic Ignition

To Turn Off Gas To Appliance:

1� Turn off fireplace using wall switch or remote control.
2� Remove the lower Horizontal access panel.

3� Turn the incoming gas control valve to "Off".
4� Replace the lower Horizontal access panel.

Lighting Instructions:

1. STOP! Read the safety information above on this label.
2. Remove the lower Horizontal access panel.
3. Turn "ON" manual "ON/OFF" switch located below the horizontal

access panel (if available).

4. Turn Incoming gas valve to the ON" position.
5. Wait 5 minutes to clear out any gas. If you smell gas, STOP! Fol-

low "B" in the safety information above on this label. If you don't

smell gas, go to the next step.

6. Turn fireplace "ON" using wall switch or remote control.
7. If the Fireplace does not light, the System will cycle through two

trials, (one minute audible clicking, thirty seconds of silence, and

then another one minute of audible clicking). If the system locks

out due to inadequate gas flow, refer to "Troubleshooting" in

instruction guide.

8. After completion of the information in the Troubleshooting section,

Repeat step 5.

9. If the system will not function correctly, follow the instructions "To

Turn Off Gas To Appliance" and call your service technician or gas

supplier.

Typical Control Module shown

Gas Valve

Manifold Pressure

Test Connection

Pilot Adjustment Screw

Hi Lo Adjustment

Inlet Pressure

Test Connection

SW1

LED1

LED2

SW1 = Programing Button
LED1 = Red Diagnostic Light
LED2 = Amber Programing Remote Control Light

Power

3.15A Fuse

Stepper Motor

Main Harness

Main ON/OFF Switch

Sensor

Igniter

SIT Proflame 2 Electronic Ignition