beautypg.com

Section 4: wiring, Installation, Installing the remote on/off wall switch – Montigo H38DF PFC User Manual

Page 19: Models included, Figure 18

background image

Page 19

XG0816 - 150204.1

H*38DF PFC Peninsula Gas Fireplace

Installation

Section 4: Wiring

Models Included

H38DFPFCN-F

HL38DFPFCN-F

HP38DFPFCN-F

H38DFPFCL-F

HL38DFPFCL-F

HP38DFPFCL-F

Figure 18.

Wiring Diagram for the SIT Proflame 2 Electronic Ignition with remote control

Honeywell (Q3450)

Pilot Assembly

Pilot Electrical

Harness Connector

Honeywell Gas

Control (SV9501M)

Gas Control

Connector

Junction Box

115VAC

24VAC

40 VA

Transformer

Black

White

Green

Gnd Screw

Wall Switch

Fan Plug

Receptacle

Figure 20. Wiring with Honeywell gas control and pilot.

Installing the remote On/Off Wall Switch

The SIT Nova 820 gas valve may be connected

to a wall switch. Do NOT connect any external

power to the remote switch. The valve will generate

its own power on a millivolt circuit Use only low

voltage wire, and NOTE: The switch location must

not exceed 30' from the fireplace.

Figure 19. Wiring with SIT Nova 820.

Models Included

H38DFPFCN

H38DFPFCL

HL38DFPFCN

HL38DFPFCL

Manifold Pressure

Test Connection

Wall Switch

Power

Generator

Pilot Adjustment Screw

Inlet Pressure

'Hi-Lo' Adjustment Knob

Gas Control Knob (Shown in “Pilot” position)

Models Included

H38DFPFCN-I

H38DFPFCL-I

HL38DFPFCN-I

HL38DFPFCL-I

NOTE: If any of the original wire supplied with the appliance is replaced,

it must be replaced with the same type, or its equivalent.

1.5V AA type

1.5V AA type

1.5V AA type

1.5V AA type

BLACK

WHITE

GREEN

To PPO

SPARK

SENSOR

RED

BLACK

BATTERY

PACK

MAIN ON/OFF

SWITCH

YELLOW/GREEN

885 PROFLAME

PILOT

BURNER

ORANGE
GREEN

BLACK

BROWN

YELLOW

ORANGE

6

10

4

6

3
4

OPTIONAL CPI/IPI SWITCH

BLUE

WHITE

X10

X11

X12

X13

X1

X6

X5

X4

X3

X2

LED Lights
LED1 - Red LED
LED2 Amber LED

3.15A FUSE

SW1

This manual is related to the following products: