Section 4: wiring, Installation, Installing the remote on/off wall switch – Montigo H38DF PFC User Manual
Page 19: Models included, Figure 18
Page 19
XG0816 - 150204.1
H*38DF PFC Peninsula Gas Fireplace
Installation
Section 4: Wiring
Models Included
H38DFPFCN-F
HL38DFPFCN-F
HP38DFPFCN-F
H38DFPFCL-F
HL38DFPFCL-F
HP38DFPFCL-F
Figure 18.
Wiring Diagram for the SIT Proflame 2 Electronic Ignition with remote control
Honeywell (Q3450)
Pilot Assembly
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Gas Control
Connector
Junction Box
115VAC
24VAC
40 VA
Transformer
Black
White
Green
Gnd Screw
Wall Switch
Fan Plug
Receptacle
Figure 20. Wiring with Honeywell gas control and pilot.
Installing the remote On/Off Wall Switch
The SIT Nova 820 gas valve may be connected
to a wall switch. Do NOT connect any external
power to the remote switch. The valve will generate
its own power on a millivolt circuit Use only low
voltage wire, and NOTE: The switch location must
not exceed 30' from the fireplace.
Figure 19. Wiring with SIT Nova 820.
Models Included
H38DFPFCN
H38DFPFCL
HL38DFPFCN
HL38DFPFCL
Manifold Pressure
Test Connection
Wall Switch
Power
Generator
Pilot Adjustment Screw
Inlet Pressure
'Hi-Lo' Adjustment Knob
Gas Control Knob (Shown in “Pilot” position)
Models Included
H38DFPFCN-I
H38DFPFCL-I
HL38DFPFCN-I
HL38DFPFCL-I
NOTE: If any of the original wire supplied with the appliance is replaced,
it must be replaced with the same type, or its equivalent.
1.5V AA type
1.5V AA type
1.5V AA type
1.5V AA type
BLACK
WHITE
GREEN
To PPO
SPARK
SENSOR
RED
BLACK
BATTERY
PACK
MAIN ON/OFF
SWITCH
YELLOW/GREEN
885 PROFLAME
PILOT
BURNER
ORANGE
GREEN
BLACK
BROWN
YELLOW
ORANGE
6
10
4
6
3
4
OPTIONAL CPI/IPI SWITCH
BLUE
WHITE
X10
X11
X12
X13
X1
X6
X5
X4
X3
X2
LED Lights
LED1 - Red LED
LED2 Amber LED
3.15A FUSE
SW1