Warning, Installation, Finishing around the fireplace – Montigo B34DV User Manual
Page 12: Wiring
Page 12
B-Series DV-2 Gas Fireplace
Part No. XG0160 -141231
Installation
Finishing Around the Fireplace
Combustible mantels and mouldings may be safely installed over the
top and on the front of the fireplace provided that they do not project
beyond shaded area shown in Figure 22 or 22a. Side wall clearances
are 3". Combustible surrounds may be installed with 3" clearance to the
side of the fireplace as shown in Figure 23.
Fireplace Facing
When selecting the finish material for your fireplace, it is important to
remember the following: THE HORIZONTAL LOUVRES MUST NOT
BE OBSTRUCTED IN ANY WAY - to do so restricts the air supply
for the control compartments and heat exchanger it also prevents
access for servicing controls.
The face of the fireplace may be painted to match the room decor,
provided you use a heat-resistant paint. Decorative facing must not
extend past the fireplace opening at all, because it will interfere with
the access to retainers for removal of glass door.
Mantels & Surrounds
NOTE: National Canadian Gas Association mantel test requirements
are for fire hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models of
fireplaces which are hot, fuel and energy efficient.
Please be aware; temperatures over the mantel will rise above normal
room temperature and walls above fireplace may be hot to touch.
Warning:
When covering the upper metal portion of the fireplace with a non-
combustible material Please Note: The decorative facing materials
may be subject to temperatures in excess of 250° F. This should be
considered when selecting facing materials.
We recommend careful consideration be given to the effects of elevated
mantel temperatures which may be in excess of product design, for
example: candles, plastic or pictures. This can cause melting, deformation,
discolouration or premature failure of T.V. and radio components.
Figure 23. Combustible surrounds.
Figure 22. Combustible mantles and facings for B34DV-2.
Figure 22a. Combustible mantles and facings for B38DV-2.
B34DV-2
B34DV-2
Wiring
WARNING
When installing the fireplace - gas lines, fittings,
accessories or any other objects cannot impede the
proper movement of the door buckles.