Installation, Warning – Montigo H38DF User Manual
Page 20

Page 20
XG0147 - 150204.1
H*38DF Gas Fireplace
Installation
Installing the remote On/Off Wall Switch
The H*38DF* gas valve may be connected to a wall switch. Do NOT
connect any external power to the remote switch. The valve will
generate its own power on a millivolt circuit or will draw its power from
an AC Connection inside the fireplace, depending on the model of the
unit. Use only low voltage wire, and DO NOT connect any external
power to the remote switch.
Refer to Figure 19, 20, or 21 for wiring requirements.
NOTE: The switch location must not exceed 30' from the fireplace.
WARNING:
An inspection of the explosion relief flappers and door
MUST be made prior to lighting the fireplace. Faulty seal
on the door gasket and/or explosion ports will result in
products of combustion leaking into the living space and
may result in carbon monoxide poisoning.