Microsonic lcs-25/DD/QP User Manual
Page 2
Technical data
Blind zone
Operating range
Maximum range
Angle of beam spread
0 to 30 mm
250 mm
0 to 65 mm
350 mm
350 mm
See detection zone
600 mm
See detection zone
Transducer frequency
Resolution, sampling rate
Reproducibility
Detection zones
for different objects:
The dark grey areas are determined
with a thin round bar (10 mm dia.)
and indicate the typical operating range
of a sensor. In order to obtain the light grey
areas, a plate (100 x 100 mm) is introduced
into the beam spread from the side.
In doing so, the optimum angle between
plate and sensor is always employed.
This therefore indicates the maximum
detection zone of the sensor.
It is not possible to evaluate ultrasonic
reflections outside this area.
320 kHz
0,18 mm
400 kHz
0,18 mm
± 0,15 %
± 0,15 %
Accuracy
Operating voltage U
B
Voltage ripple
Temperature drift internal compensated,
≤ 2%, may
be deactivated
1)
(0,17%/K without compensation
Temperature drift internal compensated,
≤ 2%, may
be deactivated
1)
(0,17%/K without compensation
9 V to 30 V DC, reverse polarity protection
±10 %
9 V to 30 V DC, reverse polarity protection
±10 %
No-load current consumption
Housing
< 60 mA
PBT
< 60 mA
PBT
ultrasonic transducer: polyurethane foam,
epoxy resin with glass content
ultrasonic transducer: polyurethane foam,
epoxy resin with glass content
Class of protection to EN 60 529
Norm conformity
Type of connection
Indicators
IP 65
EN 60947-5-2
IP 65
EN 60947-5-2
5-pin M12 initiator plug
2 three-colour LEDs
5-pin M12 initiator plug
2 three-colour LEDs
Programmable
Operating temperature
Storage temperature
Weight
Yes, with LCA-2 & LinkControl
-25°C to +70°C
Yes, with LCA-2 & LinkControl
-25°C to +70°C
-40°C to +85°C
120 g
-40°C to +85°C
120 g
Switching hysteresis
1)
Switching frequency
1)
Response time
1)
Time delay before availability
3 mm
11 Hz
5 mm
8 Hz
50 ms
< 300 ms
70 ms
< 300 ms
Order no.
Switched output
lcs-25/DD/QP
lcs-35/DD/QP
pnp, U
B
-2 V, I
max
= 200 mA
switchable NOC/NCC, short-circuit-proof
pnp, U
B
-2 V, I
max
= 200 mA
switchable NOC/NCC, short-circuit-proof
1) Can be programmed with LinkControl
0 to 200 mm
1.300 mm
2.000 mm
See detection zone
200 kHz
0,18 mm
± 0,15 %
Temperature drift internal compensated,
≤ 2%, may
be deactivated
1)
(0,17%/K without compensation
9 V to 30 V DC, reverse polarity protection
±10 %
< 60 mA
PBT
ultrasonic transducer: polyurethane foam,
epoxy resin with glass content
IP 65
EN 60947-5-2
5-pin M12 initiator plug
2 three-colour LEDs
Yes, with LCA-2 & LinkControl
-25°C to +70°C
-40°C to +85°C
120 g
20 mm
6 Hz
110 ms
< 300 ms
lcs-130/DD/QP
pnp, U
B
-2 V, I
max
= 200 mA
switchable NOC/NCC, short-circuit-proof
2 pnp switched outputs
+U
B
-U
B
D1
D2
Com
1
2
4
5
3
U
lcs-25...
lcs-35...
0 cm
5 cm
10 cm
15 cm
20 cm
25 cm
30 cm
35 cm
ausgerichtete Platte
Rohr ø 10 mm
10 cm
5 cm
0 cm
5 cm
10 cm
0 cm
10 cm
20 cm
30 cm
40 cm
50 cm
60 cm
ausgerichtete Platte
Rohr ø 27 mm
20 cm
10 cm
0 cm
10 cm
20 cm
35 cm
lcs-130...
0 m
0,4 m
0,8 m
1,2 m
1,6 m
2 m
1,3 m
ausgerichtete Platte
Rohr ø 27 mm
0,8 m
0,4 m
0 m
0,4 m
0,8 m
threaded bush
threaded bush
threaded bush
Plate
Round bar
Plate
Round bar
Round bar
Plate