4.2.7 Isolated Grounds / Differential Inputs

Optimum performance with isolated signal sources is assured with the use of the dif-
ferential input setting. The diagram below shows the recommend connections is this
configuration..

19

+

-

Input

Amp

To A/D

A/D Board

I/O

Connector

LL GND

CH High

CH Low

+

-

Sign

al So

urce

and

A/D B

oard

A

lread

y Iso

lated

.

Already isolated signal source
and A/D board connected to
a differential input.

GND

These grounds are
electrically isolated.

10 K

10K is a recommended value. You may short LL GND to CH Low
instead, but this will reduce your system’s noise immunity.