Chapter 5

Specifications

Typical for 25 °C unless otherwise specified.
Specifications in italic text
are guaranteed by design.

Output relay specifications

Table 1. Output relay specifications

Number

16

Contact configuration

16 Form C (SPDT) NO, NC and Common available at connector

Contact rating

6 amperes (A) @ 240 volts AC (VAC) or 28 volts DC (VDC) resistive

Contact resistance

100 milliohms (mΩ) max.

Operate time

10 milliseconds (ms) max.

Release time

5 ms max.

Vibration

10 to 55 hertz (Hz) (Dual amplitude 1.5 millimeters (mm))

Shock

10 G (11 ms)

Dielectric isolation

500 V (1 minute)

Life expectancy

10 million mechanical operations, min.

Power on state

Not energized. NC in contact to Common.

State after RESET
button activated

Not energized. NC in contact to Common.

Isolated inputs

Table 2. Isolated inputs specifications

Number

16

Isolation

500 volts (V)

Resistance

1.6 K ohms (Ω) min.

Input high:

+5.0 VDC min. or –5.0 VDC min.

Input low:

+1.5 VDC max. or –1.5 VDC max.

DC

Input range:

! 30 VDC max.

Input high:

4.0 V

rms

min. (50-1000 Hz)

Voltage range

AC (with filter)

Input low:

1.5 V

rms

max. (50-1000 Hz)

Without filter

20 µs

Response

With filter

5 ms

Time constant

5 ms (200 Hz)

Filter control

Software programmable at each input

Power-up

Filter setting is stored on-board and will remain at the
last stored configuration

Filters

After RESET button activated

Filters off

5-1