beautypg.com

Measurement Computing Digital488 User Manual

Page 57

background image

Section 3 Command Descriptions

3.27

Below is a summary of the Status (U0) information.

C#

Configuration

C0

All ports are inputs

C1

Port 1 is an output, ports 2 thru 5 are inputs

C2

Ports 1 and 2 are outputs, ports 3 thru 5 are inputs

C3

Ports 1 thru 3 are outputs, ports 4 and 5 are inputs

C4

Ports 1 thru 4 are outputs, port 5 is an input

C5

All ports are outputs

E# Error

Message

0

No error

1

Unrecognized command (ex. W3)

2

Illegal command option (ex. F8)

3

Conflict (attempt to output data to an input port)

4

ROM error

5

RAM error

F#

Data Format

F0 Hexadecimal
F1 ASCII
F2 Binary
F3 Decimal
F4

High Speed Binary

I###

Invert Control Lines

I0

All control and data lines are active high

I1

Inhibit output is active low

I2

Trigger output is active low

I4

Data Strobe output is active low

I8 Clear output is active low
I16

Data is active low

I32

EDR input is fallling edge sensitive

I64

Service input is falling edge sensitive

Note: the status indication reflects the sum of all received Invert commands.