Measurement Computing Digital488 User Manual
Page 57

Section 3 Command Descriptions
3.27
Below is a summary of the Status (U0) information.
C#
Configuration
C0
All ports are inputs
C1
Port 1 is an output, ports 2 thru 5 are inputs
C2
Ports 1 and 2 are outputs, ports 3 thru 5 are inputs
C3
Ports 1 thru 3 are outputs, ports 4 and 5 are inputs
C4
Ports 1 thru 4 are outputs, port 5 is an input
C5
All ports are outputs
E# Error
Message
0
No error
1
Unrecognized command (ex. W3)
2
Illegal command option (ex. F8)
3
Conflict (attempt to output data to an input port)
4
ROM error
5
RAM error
F#
Data Format
F0 Hexadecimal
F1 ASCII
F2 Binary
F3 Decimal
F4
High Speed Binary
I###
Invert Control Lines
I0
All control and data lines are active high
I1
Inhibit output is active low
I2
Trigger output is active low
I4
Data Strobe output is active low
I8 Clear output is active low
I16
Data is active low
I32
EDR input is fallling edge sensitive
I64
Service input is falling edge sensitive
Note: the status indication reflects the sum of all received Invert commands.