Getting started, 1 inspection, 2 configuration – Measurement Computing Digital232 User Manual
Page 9

Section 2
Getting Started
2.1
GETTING STARTED
2.1 INSPECTION
The Digital232 was carefully inspected, both mechanically and electrically, prior
to shipment. When you receive the interface, carefully unpack all items from the
shipping carton and check for any obvious signs of physical damage which may have
occurred during shipment. Immediately report any such damage found to the shipping
agent. Remember to retain all shipping materials in the event that shipment back to the
factory becomes necessary.
Every Digital232 is shipped with the following....
• Digital232
Digital I/O Interface
• 109-0920
Instruction Manual
• CN-6-50
50 pin card edge connector
• TR-2
115 volt Power Supply or
TR-2E
220 volt Power Supply
2.2 CONFIGURATION
Two DIP switches internal to the Digital232 set the configuration of the
interface. NOTE: Most selectable functions are read ONLY at power-on and should
only be set prior to applying power to the interface. The following figures illustrate
the factory default conditions which are:
9600 Baud
8 Data Bits
2 Stop Bits
No Parity
Xon/Xoff Disabled
Echo Disabled
Serial Terminator = CR Only