Command Descriptions

3.5

CONFIGURE Cn

Ports 1 thru 5 are configured as inputs or outputs with the Configure command.

Each port is eight bits wide. At power-on, all ports are initialized as inputs. The
Configure command is usually the first command to be sent after power on. All ports
programmed as outputs will be set to a logic zero after receiving the Configure
command. The actual output level is dependent on the Invert command (I16).

Cn Mode n (0 thru 5) defines which ports are input and output

Port

5

4

3

2

1

C0 in

in

in

in

in

C1 in

in

in

in

out

C2 in

in

in

out out

C3 in

in

out out out

C4

in

out out out out

C5

out out out out out

in = programmed as an input port
out = programmed as an output port

Example:

@

reset the Digital232

C1

select port 1 as output, ports 2 thru 5 as inputs