beautypg.com

Measurement Computing Digital232 User Manual

Page 44

background image

Section 3

Command Descriptions

3.22

I###

Invert Control Lines

I0

All control and data lines are active high

I1

Inhibit output is active low

I2

Trigger output is active low

I4

Data Strobe Output is active low

I8

Clear output is active low

I16

Data is active low

I32

EDR input is falling edge sensitive

I64

Service input is falling edge sensitive

Note: the status indication reflects the sum of all received Invert commands.

P#

Selected Port

P0

All five ports are selected

P1

Port 1 is selected

P2

Port 2 is selected

P3

Port 3 is selected

P4

Port 4 is selected

P5

Port 5 is selected

R#

Data Ready

R0

Data is sent to the host immediately

R1

Data is latched on EDR transition, and sent to the host

R2

Data is sent to the host upon receipt of the serial terminator.