beautypg.com

Mechanical, Environmental, Main connector – Measurement Computing USB-PDISO8 User Manual

Page 21: Screw terminal pinouts, Mechanical -3, Environmental -3, Main connector -3, Screw terminal pinouts -3

background image

USB-PDISO8 User's Guide

Specifications

Mechanical

Table 6. Mechanical specifications

304.3 mm (L) x 121.9 mm (W) x 20.0 mm (H),

Card dimensions

12.0" (L) x 4.8" (W) x 0.8" (H)
342.9 mm (L) x 125.7 mm (W) x 58.9 mm (H)

Enclosure dimensions

13.5" (L) x 4.95" (W) x 2.32" (H)

Environmental

Table 7. Environmental specifications

Operating temperature range

0 to 70 °C

Storage temperature range

-40 to 100 °C

Humidity

0 to 95% non-condensing

Main connector

Table 8. Main connector specifications

Connector type

Screw terminal

Wire gauge range

12 to 22 AWG

Screw terminal pinouts

Pin

Signal Name

Pin

Signal Name

IP0A

Input 0 terminal A

IP4A

Input 4 terminal A

IP0B

Input 0 terminal B

IP4B

Input 4 terminal B

IP1A

Input 1 terminal A

IP5A

Input 5 terminal A

IP1B

Input 1 terminal B

IP5B

Input 5 terminal B

IP2A

Input 2 terminal A

IP6A

Input 6 terminal A

IP2B

Input 2 terminal B

IP6B

Input 6 terminal B

IP3A

Input 3 terminal A

IP7A

Input 7 terminal A

IP3B

Input 3 terminal B

IP7B

Input 7 terminal B

0-NC

Relay 0 Normally Closed contact

4-NC

Relay 4 Normally Closed contact

0-C

Relay 0 Common contact

4-C

Relay 4 Common contact

0-NO

Relay 0 Normally Open contact

4-NO

Relay 4 Normally Open contact

1-NC

Relay 1 Normally Closed contact

5-NC

Relay 5 Normally Closed contact

1-C

Relay 1 Common contact

5-C

Relay 5 Common contact

1-NO

Relay 1 Normally Open contact

5-NO

Relay 5 Normally Open contact

2-NC

Relay 2 Normally Closed contact

6-NC

Relay 6 Normally Closed contact

2-C

Relay 2 Common contact

6-C

Relay 6 Common contact

2-NO

Relay 2 Normally Open contact

6-NO

Relay 6 Normally Open contact

3-NC

Relay 3 Normally Closed contact

7-NC

Relay 7 Normally Closed contact

3-C

Relay 3 Common contact

7-C

Relay 7 Common contact

3-NO

Relay 3 Normally Open contact

7-NO

Relay 7 Normally Open contact

4-3