Specifications
Typical for 25°C unless otherwise specified.
Specifications in italic text are guaranteed by design.
Relay specification
Table 1. Relay output specifications
Number
8
Contact configuration
8 FORM C (SPDT) NO, NC and Common available at connector
Contact rating
6 amperes (A) @ 240 volts AC (VAC) or 28 volts DC (VDC) resistive
Contact resistance
100 milliohms (mΩ) max
Operate time
10 milliseconds(ms) max
Release time
5 ms max
Vibration
10 to 55 hertz (Hz) (Dual amplitude 1.5 millimeters (mm))
Shock
10 G (11 ms)
Dielectric isolation
500 V (1 minute)
Life expectancy
10 million mechanical operations, min
Power on RESET state
Not energized. NC in contact to Common.
Isolated inputs
Table 2. Isolated input specifications
Number
8
Isolation
500 volts ( V)
Resistance
1.6 K ohms (Ω) min.
Input high:
+5.0 VDC min or –5.0 VDC min
Input low:
+1.5 VDC max. or –1.5VDC max.
DC
Input range:
30 VDC max
Input high:
6.0 V
rms
min (50-1000 Hz)
Voltage range
AC (with filter)
Input low:
1.5 V
rms
max (50-1000 Hz)
w/o filter
20 µs
Response
w/ filter
5 ms
Time constant
5 ms (200 Hz)
Filter control
Software programmable at each input.
Filters
Power-up /reset
Filters off