beautypg.com

Analog output, Timebase, Digital input/output – Measurement Computing USB-231 User Manual

Page 23

background image

USB-231 User's Guide

Specifications

23

Analog output

Table 3. Analog output specifications

Parameter

Condition

Specification

Resolution

16 bits, 1 in 65,536

Output range

±10 V

Number of channels

2

Update rate

Hardware paced

5 kS/s simultaneous per channel max, hardware-paced

Trigger sources

Software, TRIG

Output current drive

±5 mA

Short circuit current

±11 mA

Slew rate

3 V/µs

Output impedance

0.2 Ω

Absolute accuracy (no load)

Typical at full scale

8.6 mV

Maximum over temperature,
full scale

32 mV

INL

±4 LSB

DNL

16 bits no missing codes

Power-on state

0 V

Startup glitch

–7 V for 10 µs

Timebase

The following specifications apply to hardware-paced analog input and analog output sampling accuracy.

Parameter

Specification

Timebase frequency

80 MHz

Timebase accuracy

±100 ppm

Timing resolution

12.5 ns

Digital input/output

Table 4. Digital I/O specifications

Parameter

Specification

Compatibility

LVTTL, 3.3 V LVCMOS

Number of channels

8 (DIO0 through DIO7)

Configuration

Each bit can be configured as input (power on default) or output

Pull-down resistor

47.5 k

Ω to digital ground (GND).

Absolute maximum voltage
range

–0.3 V to 5 V with respect to digital ground (GND)