Specifications, Analog input, Chapter 4 – Measurement Computing USB-231 User Manual
Page 22
22
Chapter 4
Specifications
All specifications are subject to change without notice.
Typical for 25 °C unless otherwise specified.
Specifications in italic text are guaranteed by design.
Analog input
Table 1. Analog input specifications
Parameter
Condition
Specification
A/D converter type
Successive approximation
ADC resolution
16 bits
Sampling rate
Maximum aggregate
50 kS/s
Number of channels
8 single-ended or 4 differential; software-selectable
Input voltage range
±10 V
Working voltage
±10 V
Overvoltage protection
Power on
±30 V max
Power off
±20 V max
Input impedance
>1 GΩ
Input bias current
±200 pA, typ
INL
±1.8 LSB
DNL
16 bits no missing codes
CMRR
56 dB (DC to 5 kHz)
Input bandwidth
300 kHz
Trigger sources
Software, TRIG
Absolute accuracy (analog input DC voltage measurement accuracy)
Table 2. Absolute accuracy (no load)
Range
At full scale (typical at 25 °C)
At full scale (maximum over temperature)
System noise
±10 V
6 mV
26 mV
0.4 mVrms