beautypg.com

20 ~aa3evv – Measurement Computing CB-COM-7013 User Manual

Page 37

background image

37

CB-7013, CB-7033 User’s Manual

2.20 ~AA3EVV

Description: Set Host Watchdog Time-out Value
Syntax: ~AA3EVV[CHK](cr)
~

Delimiter character.

AA

Address of setting module (00 to FF).

3

command for set host watchdog time-out value.

E

1=Enable/0=Disable host watchdog.

VV

Time-out value, from 01 to FF, each for 0.1 second.

Response:

Valid Command:

!AA[CHK](cr)

Invalid Command:

?AA[CHK](cr)

Syntax error or communication error may get no
response.

!

Delimiter for valid command.

?

Delimiter for invalid command.

AA

Address of response module (00 to FF).

Example:
Command: ~013164

Receive: !01

Set address 01 enables host watchdog and time-out value is

set to 64 (10.0 seconds); returns successful.

Command: ~012

Receive: !0164

Read address 01 host watchdog time-out value. Return 64,

the time-out value is 10.0 seconds.

Related Command:

Sec. 2.16

~**, Sec. 2.17 ~AA0, Sec. 2.18 ~AA1, Sec. 2.19 ~AA2

Related Topic:

Sec. 3.2

Module Status; Sec. 3.3, Dual Watchdog Operation

This manual is related to the following products: