11 $aa9(data) – Measurement Computing CB-COM-7013 User Manual
Page 28

28
CB-7013, CB-7033 User’s Manual
2.11 $AA9(Data)
Description: Set LED Data
Note: The command is for CB-7013D/33D only.
Syntax: $AA9(Data)[CHK](cr)
$
Delimiter character
AA
Address of setting module (00 to FF)
9
Command for set LED data
(Data)
Data for display on the LED, from
−
19999. to +19999.
The data needs a sign, five digits and a decimal point.
Response:
Valid Command:
!AA[CHK](cr)
Invalid Command:
?AA[CHK](cr)
Syntax error or communication error may get no
response.
!
Delimiter for valid command.
?
Delimiter for invalid command or LED not set to host
control.
AA
Address of response module (00 to FF)
Example:
Command: $019+123.45
Receive: !01
Send address 01 LED data +123.45, return successful
Command: $029+512.34
Receive: ?02
Send address 02, LED data +512.34. Return indicates the LED
is not in the host mode.
Related Command:
Sec. 2.9
$AA8, Sec. 2.10 $AA8V