beautypg.com

Measurement Computing CB-COM-7013 User Manual

Page 19

background image

19

CB-7013, CB-7033 User’s Manual

2.2 #**

Description: Synchronized Sampling
Syntax: #**[CHK](cr)
#

A delimiter character.

**

Synchronized sampling command.

Response:

No response

Example:
Command:

#**

No response

Send synchronized sampling command.

Command: $014

Receive: >011+025.123

First read, get status=1

Command: $014

Receive: >010+025.123

Second read, get status=0

Related Command:

Sec. 2.8

$AA4

Note: The command is for CB-7013/13D only.