beautypg.com

Kemppi Pulse 350 User Manual

Page 9

background image

EN

2.5.2 gas cooled system: KempArc pulse + dt 400

1.

4.

6.

7.

2.

8.

3.

5.

1.

Dt 400 wire feed unit

2.

Kemparc pulse power source

3.

gas supply

4.

gas cooled welding gun

5.

power cable

6.

earth return lead and clamp

7.

KF 62 remote panel (optional)

8.

robot controller

2.5.3 Connecting to mains power

Kemparc power sources are delivered as standard with 5 meters of mains power cable. no

mains plug is fitted at the Kemppi factory.

NOTE!

If local country based regulations state an alternative power cable is required, the mains

cable must be replaced in conformity with the regulations. Connection and installation of the

mains cable and plug, should only be carried out by a suitably qualified person.
remove the machine cover plate to enable mounting of a mains cable. Kemparc pulse power

sources can be connected to the mains supply of 400 V 3~ .

7

Kemp

a

rc

pulse 350, 450 / © Kemppi O

y / 1044

This manual is related to the following products: