beautypg.com

Kemppi Pulse 350 User Manual

Page 26

background image

EN

reaDY tO WelD: Your basic welding selection and set-up is now complete. You are ready

to weld, providing you select the corresponding channel ‘Job’ number on the KF 62 remote

control panel. Set your welding power and arc length and weld.

NOTE!

If you SeLeCt ‘MIG’ (i.e. Basic MIG/MAG selection in the above listing) you will automatically

jump from item 4 to item 9. When you have saved your channel ‘Job’ number selection, you will

have access to basic MIG/MAG welding on this channel. Voltage and wire feed speed are then

selected in the normal way.

memory ‘job’ Channels

So there is a maximum of 100 x channels available for a variety of welding ‘Job’s or welding

projects.
Welding parametres can be quickly saved to memOrY ‘Job’ CHannel numbers and recalled

later or updated later unless ‘locked’ via the four digits aDminiStratOr pin code lock.

K 60 – Fast Function Keys

the fast function keys, F1 and F3 are short cut keys.

• F1 CHannel inFO – Display the basic data recorded to the displayed channel.

• F3 WF# – Displays active and selected wire feed unit and allows a new WFu selection.

Kemparc pulse allows up to 7 x wire feed units to be connected to one power source.

NOTE!

only one wire feed unit can be active at any one time and must be selected before it will

operate.

24

Kemp

a

rc

pulse 350, 450 / © Kemppi O

y / 1044

This manual is related to the following products: