systEm ConFIg mEnu

(in main menu 4/7)

Water Cooling

Water Cooler control:

OFF / AUTO / ON.

Factory setting: AUTO

OFF: Water Cooler always OFF.

AUTO: Water Cooler automatic control

ON. Water Cooler starts when welding

starts and is turned off after a delay when

welding stops.

ON: Water Cooler is always ON.

Cable Length

Cable length: 10m -

100m, 5m steps.

Factory Setting: 10m.

Welding cable loop length setting for

optimising arc control.

FineCalib

Fine Tuning

Calibration Point:

0V/100A –

100V/100A,

1V steps.

Factory Setting: 10V/100A.

Compensation for varying cable resistance.

System Clock

System Clock Settings.

Device

Information

System Device information:

DevSW: Unit Software Version.

SysSW: System Software Version (Base software version).

BootSW: Boot Software Version.

SW Item: Software Item Number (IFS number).

Serial: Device Serial number.

Prog: Programmer name

Date: Programming date.

Restore Settings

User 1 (one of ten users) Channel:

Selected user can restore to his backup memory channels one by one.

Other users’ memory channels remain untouched.

Setup settings remain untouched.
User 1 (one of ten users) All Channels:

Selected user can restore all of his backup memory channels (0-9) at one time.

Other users’ memory channels remain untouched.

Setup settings remain untouched.
Restore To Factory:

All channels (of all users) are removed.

All users’ backup channels are removed.

All setup settings are set to defaults.

Licence Code

Entering Licence Code numbers:

Up/Down arrows are used to select the code number position.

Pulse encoder is used to select the code number (0-255) to be entered.

Soft Key Button on the right is used to activate the license number (after all numbers have been

entered). In case the code was wrong the earlier view will be displayed.

WeldData Delay

Adjustment Range:

1s – 60s

1s steps.

Factory Setting: 20s.

Defines how long the Weld Data is

displayed after Welding Ends.

Weld Data display is also turned off when

pulse encoder is turned or any button is

pressed.

Display Delay

Adjustment Range:

1 – 20

1 steps.

Factory Setting: 10.

Defines how long time the information is

displayed (like: “Setting Saved” text). This is

not always the exact time.

Pre Gas Time

Pre Gas Time setting:

0.0s – 9.9s – CURVE,

0.1s steps.

Factory Settings: CURVE.

CURVE: Pre Gas time is read from the

Welding Curve.

0.0 - 9.9s: User Pre Gas time setting.

Post Gas Time

Post Gas Time setting:

0.0s – 9.9s - CURVE

0.1s steps.

Factory Settings: CURVE.

CURVE: Pre Gas time is read from the

Welding Curve.

0.0 - 9.9s: User Post Gas time setting.