Cable

Duty cycle ED

Voltage loss / 10 m

100 %

60 %

30 %

70 mm²

355 A

460 A

650 A

0.25 V / 100 A

95 mm²

430 A

560 A

790 A

0.18 V / 100 A

Do not overload welding cables due to voltage losses and heating.

NOTE!

Always check the serviceability of the earth return cable and clamp. ensure the metal

surface to which the cable is connected is clean from metal oxide or paint. Check the connector to

the power source is fastened correctly.

2.5.6 Interconnection with wire feeder

Kemppi provide a choice of interconnection cable sets for different environments. Only

materials that meet the demands of Kemppi's international markets are used in their

construction.
used correctly, Kemppi cables sets ensure high welding performance and serviceability.
Before use, always ensure the cable set is in good condition and that connectors are correctly

fastened. loose connections reduce welding performance and may result in damage to

connectors due to heating effects.
For correct connection and configuration of cable sets, please refer to schematic drawings:

2.4.1 and 2.4.2

NOTE!

KempArc Pulse 350/450 power sources are designed to be used oNLY with Dt 400 wire feed

unit and KF 62 control panel.

3.

opErAtIon Control

3.1

mAIn swItCh I/o

When you turn the on/off switch into i -position, the pilot warning lamp is illuminated and

the machine is ready for use. always turn the machine on and off with the power source mains

switch. never use the mains plugs as a switch.

3.2

pIlot lAmps

the pilot lamps of the machine report its operational state:
the green pilot lamp when lit, indicates that the machine is switched on and ready for

use, and that it is connected to the mains supply with the power source main switch in the

i-position.
When lit, the orange lamp indicates that the thermal protection circuit has been activated due

to higher than normal working loads that exceed the rated duty cycle. the cooling fan will

continue to run and cool the machine down. When the lamp is off the machine is again ready

to weld.

3.3

opErAtIon oF CoolIng FAn

Kemparc pulse power sources incorporate two simultaneously operating fans.

• the fan is started momentarily when the main switch is placed into position - i.

• the fan will start during welding as the machine reaches operational temperature, and

it will run for 1 to 10 minutes after the welding has stopped, depending on the welding

cycle completed.