5.12 gEttIng stArtEd

step by step for the first time user

First select your language

NOTE!

the default menu language is english. In the following steps you will be able to select

alternative languages
1.

Connect mains power and switch on power source. if this is the initial system activation you

may need to press and hold the large orange On/OFF button on K 60 panel. top left -

long press (approximately 5 seconds).

2.

now press button marked ‘menu’ to display main menu listing. there are 8 x items in this

main menu list. as you select each item in the list, the reference number (Bottom

middle display) will change e.g. 2/7 or 5/7 etc, showing which menu item you have

selected. (You can cycle from first to last or last to first in a loop in all menu lists, if you

wish). a black arrow marks your menu item selected.

3.

menu items are selected via the up-DOWn buttons marked with orange arrows. these

buttons are situated underneath the encoder knob to the right of the panel. move the

‘black arrow cursor’ up and down the menu lists. press down arrow button selecting item

5/7 marked language. press soft key button underneath the word SeleCt.

4.

make your language choice as detailed above, and then press the SeleCt/SaVe button (right-

hand button next to menu button). Your language choice is now confirmed and will

remain selected unless you change it later.

new channel job number

Kemparc pulse is designed for production jobs as well as varied specialist operation. main

welding set-up is made through the K 60 menu and recorded to a ‘Channel (Job) number’ of

your choice.
When you want to weld you simply select the corresponding channel (Job) number on the

wire feeder control panel KF 62 and start welding. Only the most often used controls are

available in the KF 62 control panel, making welding easy and convenient.

NOTE!

If the machine is new and no welding has been completed before, follow these steps.

a. Switch on power source (may require long press of panel On/OFF button - 5 sec).

1.

press and select neW button.

2.

Create new Channel – press SeleCt button.

3.

Choose weld process and press SeleCt button.

B. then follow the steps from item 4 in the list below.

Editing an existing channel (job) number

1.

press button marked ‘menu’ to show main menu listing.

2.

SeleCt ‘edit Channel’ - press SeleCt button

3.

SeleCt ‘Select Weld Curve’ - press SeleCt button

4.

Choose and SeleCt process. mig/1-mig/pulse mig/Double pulse mig/ or Curve number list -

press SeleCt button

5.

Choose and SeleCt material group - press SeleCt button

6.

Choose and SeleCt material grade - press SeleCt button

7.

Choose and SeleCt filler wire diameter - press SeleCt button

8.

Choose and SeleCt shielding gas - press SeleCt button

9.

Choose and SeleCt curve - press SeleCt button. (note: the curve(s) presented in this view are

based on your previous selections from items 4 through to 8.)

10. Choose and SaVe memory channel number. memory channel selections are made using

either the White +/- buttons Or Orange up-DOWn buttons - press SaVe button