Technical data – Kemppi Pulse 350 User Manual
Page 31

EN
11. tEChnICAl dAtA
KempArc Pulse 350
KempArc Pulse 450
Connection voltage
3~50/60 Hz
400 V -15 %...+20 %
400 V -15 %...+20 %
Rated power
60 % ED
22.1 kVA
80 % ED
16.0 kVA
100 % ED
15.3 kVA
17.8 kVA
Connection cable
HO7RN-F
4G6 (5 m)
4G6 (5 m)
Fuse (delayed)
25 A
35 A
Load capacity 40 °C
60 % ED
450 A
80 % ED
350 A
100 % ED
330 A
350 A
Welding current and voltage range
10 V ... 50 V
10 V ... 50 V
Open circuit voltage
50 V
50 V
Open circuit power
100 W
100 W
Power factor at max. current
0.85
0.9
Efficiency at max. current
88 %
88 %
Operating temperature range
-20 º C ... +40 º C
-20 º C ... +40 º C
Storage temperature range
-40 º C ... +60 º C
-40 º C ... +60 º C
EMC class
A
A
Degree of protection
IP23S
IP23S
Minimun short circuit power S
sc
of
supply network *
5.5 MVA
5.5 MVA
External dimensions
L x W x H
590 x 230 x 430 mm
590 x 230 x 430 mm
Weight
36 kg
36 kg
Voltage supply for auxiliary devices
50 V DC / 100 W
50 V DC / 100 W
Fuse (delayed)
6.3 A
6.3 A
Voltage supply for cooling unit
24V DC / 50 VA
24V DC / 50 VA
* See paragraph 2.4
29
Kemp
a
rc
pulse 350, 450 / © Kemppi O
y / 1044